Rich Electric Co. “SuperCombi” User Manual V7.19 Copyright 2009
Page 109
G1-04: Start Batt Low Volt
Main Menu>Programming>ENT> DC Generator >ENT
z
Use constant G1-04 to adjust the DC Generator disconnection voltage. When the input supply
voltage is lower than the value set in constant G1-04 (0~16V), and longer than time set in
constant G1-05 (0~255 sec), the DC Generator input will be disconnected.
z
Disconnecting from the House Batteries from the Starter Battery.
G1-05: Start Batt Low Time
Main Menu>Programming>ENT> DC Generator >ENT
z
Use constant G1-05 to determine the disconnection detection time. When the input voltage is
Lower than the value set in G1-04, for longer than the time set in constant G1-05. Value in
Seconds 0-255. The DC Generator input will be disconnected.
E.g. if the Start Battery Full Time (G1-03) = 120sec and Start Battery Full voltage was set to
13.3v , (G1-02)=13.3v
Once the input voltage connected DC Generator input remains above the value set in G1-02
eg 13.3v the DC Generator input will wait for the set time “Start Battery Full Time” G1-03
(20sec) before allowing the charger to be connected to the house batteries. This is useful when
charging from a starter battery as it will give the starter battery time to replenish its charge first
before charging the house batteries.
G1-06: House Batt Full Volt
Main Menu>Programming>ENT> DC Generator >ENT
z
Use constant G1-06 to adjust the House battery “Full” voltage. This voltage will turn “ON” the
reverse charging cycle. Allowing for the excess power from the house batteries to recharge the
starter battery.
G1-07: House Batt Full Time
Main Menu>Programming>ENT> DC Generator >ENT
z
Use constant G1-07 to determine the connection detection time. Once the house battery voltage
is higher than G1-06, and longer than for the set time in constant G1-07, The DC Gen Rev
Charging output will be connected. Value in Seconds 0-255.
Note: G1-06 & G1-07 is helpful when charging from a start battery (battery to battery).
Once the house batteries are “Full” excess power being generator from solar, wind, or even the
AC Charger will allowed to be sent to the Starter batteries. Allowing for Bi-Directional
charging.
Summary of Contents for Invertek SuperCombi SC-1500-12X
Page 1: ......
Page 2: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 2...
Page 9: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 9 Layout...
Page 125: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 125 Chapter 8 Constants list...
Page 155: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 155 NOTES...