O2-07: RUN/STOP Key Hold Time
Main Menu>Programming>ENT>Operator>ENT>Key Selections>ENT>
z
Use constant O2-07 to set the time it takes to press RUN/STOP key to activate its
function.
z
Initial setting=2 sec, setting range: 2~10 sec.
O2-08: Power ON Auto Run Select
Main Menu>Programming>ENT>Operator>ENT>Key Selections>ENT>
z
Use constant O2-08 to select to auto run manually or automatically.
Setting Function
O2-08=0
Auto Run is active when pressing Run/STOP key
O2-08=1
(Initial setting)
Auto Run is active when the power is on.
O2-09: LCD Display Idle Time Set
Main Menu>Programming>ENT>Operator>ENT>Key Selections>ENT>
z
When O2-09=0, Display Idle Function is disabled.
z
Use constant O2-09 to set the idle time when the keypad is not operated and all the
LCD Display and LED Indicators of the SuperCombi® entering the idle mode which
only RUN/STOP indicator is active.
z
Once any key on the panel is pressed, it will return to the display before Idle status.
z
Initial setting=10 min, setting range: 0~60 min.
O2-10: System Time Setting
Main Menu>Programming>ENT>Operator>ENT>Key Selections>ENT>
z
Use constant O2-10 to set the system time. Format is hh:mm, “hh” is hour (0~23) and
“mm” is minute (00~59).
O2-11: System Date Setting
Main Menu>Programming>ENT>Operator>ENT>Key Selections>ENT>
z
Use constant O2-11 to set the system date. Format is yy-mm-dd, “yy” is year (0~99),
“mm” is month (01~12), and “dd” is date (01~31).
Summary of Contents for Invertek SuperCombi SC-1500-12X
Page 1: ......
Page 2: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 2...
Page 9: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 9 Layout...
Page 125: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 125 Chapter 8 Constants list...
Page 155: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 155 NOTES...