H2-07: Over Voltage Cut In
Main Menu>Programming>ENT> DC Controller 2 >ENT
z
Use constant H2-07 to adjust the DC Load “over voltage” reconnection Input voltage. This
voltage will turn “ON” the DC Load output again to allow output supply.
H2-08: Timer 1 ON Time”
Main Menu>Programming>ENT> DC Controller 2 >ENT
z
Use constant H2-08 to switch DC Controller 2 ON. When the timer One has reached the first set
of time specified by H2-08, DC Controller 2 will be switched ON.
Note: If H2-08=00:00, then H2-08 is ignored.
H2-09: Timer 1 OFF time
Main Menu>Programming>ENT> DC Controller 2 >ENT
z
Use constant H2-09 to switch DC Controller 2 OFF. When the system time has reached the first
set of time specified by H2-09, DC Controller 2 will be switched OFF.
Note: If H2-09=00:00, then H2-09 is ignored.
H2-10: Timer 2 ON Time
Main Menu>Programming>ENT> DC Controller 2 >ENT
z
Use constant H2-10 to switch DC Controller 2 ON. When the system time has reached the
second set of time specified by H2-10, DC Controller 2 will be switched ON.
Note: If H2-10=00:00, then H2-10 is ignored.
H2-11: Timer 2 OFF time
Main Menu>Programming>ENT> DC Controller 2 >ENT
z
Use constant H2-11 to switch DC Controller 2 OFF. When the system time has reached the
second set of time specified by H2-10, DC Controller 2 will be switched OFF.
Note: If H2-10=00:00, then H2-10 is ignored
H2-12: Manual OverRide Time
Main Menu>Programming>ENT> DC Controller 1 >ENT
z
Use constant H2-12 to determine the minimum “Over Ride” time.
z
The DC Load can be manually overridden. This is useful when the House batter is low and you
need to operate a load for a short period of time or testing purpose. When in over ride mode the
DC Load will not be switched ON within the time specified time, Value in Seconds 0-255.
※
Note: OFF conditions of 0 Sec, ignore this setting.
Summary of Contents for Invertek SuperCombi SC-1500-12X
Page 1: ......
Page 2: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 2...
Page 9: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 9 Layout...
Page 125: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 125 Chapter 8 Constants list...
Page 155: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 155 NOTES...