Rich Electric Co. “SuperCombi” User Manual V7.19 Copyright 2009
Page 139
Menu
Group
Function
Constant
LCD Display
Range
Unit
Factory
Remark
G1-01
DC/DC Switch Enable
0~1
0
0:Disable
1:Enable
G1-02
Start Batt Full Volt
0~16V
0.01V
13.3V
G1-03
Start Batt Full Time
0~255sec
1sec
20sec
G1-04 Start
Batt
Low
Volt
0~16V 0.01V 12.8V
DC
Generator
“Input”
G1-05
Start Batt Low Time
0-255sec
1sec
10 sec
DC Generator Reverse
Charging Bi-Directional
NOTE 5
G1-06
House Batt Full Volt
0~16V
0.01V
14.4V
G1-07
House Batt Full Time
0~255sec
1sec
60 sec
G1-08
House Batt Low Volt
0~16V
0.01V
13.2V
G1-09
House Batt Low Time
0~255sec
1sec
20 sec
G1-10 Over
Voltage
CutOut
0~16V 0.01V 15.2V
G1-11
Over Voltage Cut in
0~16V
0.01V
14.9V
G1-12
Min Switch ON Time
0~255sec
1sec
10 sec
G DC
Generator
G1
DC
Generator
“Output”
G1-13 Manual
OverRide
Time
0~255sec
1sec 60sec
H1-01
DC Load Enable
0~1
0
0:Disable
1:Enable
H1-02
Low Voltage
Disconnect
0~16V 0.01V 13.3V
H1-03
Low Volttage for ? sec
0~255sec
1sec
20 sec
H1-04 Reconnect
Voltage”
0~16V 0.01V 12.8V
H1-05
Reconnect for ? sec
0~255sec
1sec
10sec
H1-06 Over
Voltage
Cut
Out 0~16V 0.01V 15.2V
H1-07
Over Voltage Cut In
0~16V
0.01V
14.9V
Programming
H DC
Controller
H1 DC
Out
No:1
H1-08 Manual
OverRide
Time
0~255sec
1sec 60sec
Summary of Contents for Invertek SuperCombi SC-1500-12X
Page 1: ......
Page 2: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 2...
Page 9: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 9 Layout...
Page 125: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 125 Chapter 8 Constants list...
Page 155: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 155 NOTES...