680 Synergy Plus – Digital Weight Indicator
54
Visit our website
lists the default 680 print formats:
The <G2>, <N2> and <T2> tokens (
) print the gross, net and tare weights in the units not currently displayed
on the indicator.
The 1000 character limit of each print format string includes the output field length of the print formatting tokens, not
the token length. For example, if the indicator is configured to display a decimal point, the <G> token generates an
output field of 13 characters: the 10 character weight value (including decimal point), one space, and a two-digit units
identifier.
PT (preset tare) is added to the tare weight if tare was keyed in.
8.2 Customizing Print Formats
The GFMT, NFMT, ACUMFMT, STPTFMT and HDRFMT formats can be customized using the print format menu (
PForMT
) via
the front panel. See
for the print format menu structure. To access the print format menu the indicator
must be in setup mode (
).
8.2.1 Using the Front Panel
Use the print format menu to customize the print formats and to edit the print format strings by changing the ASCII characters in
the format string. See
for the alphanumeric entry procedure to edit the print format string.
Some characters cannot be displayed on the 680 front panel, see the ASCII character chart in
for available characters. The 680 can send or receive ASCII characters; the character printed depends on the
particular ASCII character set implemented for the receiving device.
Format
Default Format String
When Used
GFMT
GROSS<G><NL2><TD><NL>
Weigh mode
–
no tare in system
NFMT
GROSS<G><NL>TARE<SP><T><NL>NET<SP2><N>
<NL2><TD><NL>
Weigh mode
–
tare in system
ACUMFMT
ACCUM <A><NL><DA> <TI><NL>
Accumulator demand print format string
STPTFMT
<SCV><SP><SPM><NL>
Setpoint print operation with PSHPRNT=ON
HDRFMT1-2
COMPANY NAME<NL>STREET ADDRESS<NL>CITY ST ZIP<NL2>
Table 8-2. Default Print Formats
Note