7.4 Parameter Setting Commands
Parameter setting commands allow the current value for a configuration parameter to be displayed or changed.
Current configuration parameter settings can be displayed in setup mode or weigh mode using the following syntax:
command<ENTER>
Most parameter values can be changed in setup mode only; setpoint parameters listed in
changed when in normal weigh mode.
Use the following command syntax when changing parameter values: command=value<ENTER>, where
value
is either a
number or a parameter value. Use no spaces before or after the equal (=) sign. If an incorrect command is typed or an invalid
value is specified, the indicator returns
??
followed by the error message.
Example: to set the motion band parameter on Scale #1 to 5 divisions, type the following:
SC.MOTBAND#1=5<ENTER>
To return a list of the available values for parameters with specific values, enter the command and equal sign, followed by a
questions mark (command=?<ENTER>). The indicator must be in setup mode to use this function.
After changes are made to configuration parameters using EDP commands, use the
KSAVE
or
KSAVEEXIT
commands to
commit the changes to memory.
The user must stop the current batch for new values to take effect.
Command
Description
Values
SC.CAPACITY#n
Scale capacity
0.0000001–9999999.0,
10000.0
(default)
SC.ZTRKBND#n
Zero track band (in display divisions)
0.0–100.0,
0.0
(default)
SC.ZRANGE#
n
Zero range (%)
0.0–100.0,
1.9
(default)
SC.MOTBAND#
n
Motion band (in display divisions)
0–100,
1
(default)
SC.SSTIME#
n
Standstill time (in 0.1 second intervals; 10 = 1 second) 0–600,
10
(default)
SC.OVERLOAD#
n
Overload
FS+2%
(default), FS+1D, FS+9D, FS
SC.WMTTHRH#
n
Weighment threshold
0.0–9999999.0,
1000.0
(default)
SC.NUMWEIGH#
n
Number of weighments
0–4294967295 (uint_32_t_max),
0
(default)
SC.MAX_WEIGHT#
n
Maximum weighment
-9999999–9999999,
0
(default)
SC.MAX_DATE#
n
Date of maximum weighment
Up to 25 alphanumeric characters
SC.DIGFLTR1#
n
SC.DIGFLTR2#
n
SC.DIGFLTR3#
n
Number of A/D samples averaged for the individual
stages (1-3) of the three stage digital filter
1, 2, 4,
8
(default), 16, 32, 64, 128, 256
SC.DFSENS#
n
Digital filter cutout sensitivity
2OUT
(default), 4OUT, 8OUT, 16OUT, 32OUT, 64OUT, 128OUT
SC.DFTHRH#
n
Digital filter cutout threshold
NONE
(default), 2D, 5D, 10D, 20D, 50D, 100D, 200D, 250D
SC.RATLTRAP#
n
Rattletrap filtering
OFF
(default), ON
SC.SMPRAT#
n
Scale A/D sample rate
6.25HZ, 7.5HZ, 12.5HZ, 15HZ, 25HZ,
30HZ
(default), 50HZ,
60HZ, 100HZ, 120HZ
SC.PWRUPMD#
n
Power up mode
GO
(default), DELAY
SC.TAREFN#
n
Tare function
BOTH
(default), KEYED, NOTARE, PBTARE
SC.PRI.FMT#
n
Primary units format (decimal point and
display divisions)
8888100, 8888200, 8888500, 8888810, 8888820, 8888850,
8888881
(default), 8888882, 8888885, 888888.1, 888888.2,
888888.5, 88888.81, 88888.82, 88888.85, 8888.881, 8888.882,
8888.885, 888.8881, 888.8882, 888.8885, 88.88881, 88.88882,
88.88885, 8.888881, 8.888882, 8.888885
SC.PRI.UNITS#
n
Primary units
LB
(default), KG, OZ, TN, T, G, CUSTOM, NONE
SC.SEC.FMT#
n
Secondary units format (decimal point and
display divisions)
8888100, 8888200, 8888500, 8888810, 8888820, 8888850,
8888881, 8888882, 8888885, 888888.1, 888888.2,
888888.5
(default), 88888.81, 88888.82, 88888.85, 8888.881,
8888.882, 8888.885, 888.8881, 888.8882, 888.8885, 88.88881,
88.88882, 88.88885, 8.888881, 8.888882, 8.888885
SC.SEC.UNITS#
n
Secondary units
LB,
KG
(default), OZ, TN, T, G, CUSTOM, NONE
For commands ending with
#n
, n is the scale number (1)
Table 7-4. Scales Commands