4.4.4.1 Serial Port Menu
Figure 4-9. Communication – Serial Port Menu
Parameter
Description
input
Input – Sets the input trigger type;
Settings:
CMD
(default) – Command: setting input trigger to command allows operation of EDP commands and can print
STRIND – Stream Industrial Scale Data: data is updated up to the configured sample rate; allows operation of
EDP commands and printing
STRLFT
–
Stream Legal for Trade Data: data is updated at the configured display update rate; allows operation of
EDP commands and printing
REMOTE
– Configures the port to operate as a serial scale input
NOTE: When in STRIND, STRLFT and REMOTE, if the COMM port is set to RS485, the port does not stream data and cannot
be used in a local/remote application
baud
Baud Rate – Sets the transmission speed for the port;
Settings: 1200, 2400, 4800,
9600
(default), 19200, 28800, 38400,
57600, 115200
bits
Data Bits – Sets number of data bits transmitted or received by the port and specifies the parity bit to odd, even or none;
Settings:
8NONE
(default), 7EVEN, 7ODD
stopbit
Stop Bits – Sets the number of stop bits transmitted or received by the port;
Settings:
1
(default), 2
termin
Outgoing Line Termination – Sets the termination character for data sent from the port;
Settings:
CR/LF
(default), CR
eoldly
End of Line Delay – Sets the delay period from when a formatted line is terminated to the beginning of the next
formatted serial output (measured in milliseconds);
Enter value: 0–255,
0
(default)
echo
Echo – Specifies if characters received by the port are echoed back to the sending unit;
Settings:
ON
(default), OFF
respnse
Response – Specifies if the port transmits replies to serial commands;
Settings:
ON
(default), OFF
handshk
Port Handshaking – Specifies if XONXOFF flow control characters are used (RS-485 only);
Settings:
OFF
(default),
XONXOFF, HRDWAR
address
Address – Specifies address used to connect to the port (RS-485 only);
Enter value: 0–255,
0
(default)
Table 4-8. Communication – Serial Port Menu Parameters
Setup
Comm
SERIAL
input
BAUD
RS232 1-2
BITS
StopBIT
TERMIN
EOLDLY
ECHO
ReSPNSE
input
BAUD
RS485
BITS
TERMIN
EOLDLY
ECHO
HaNDSHK
ADDRess
StopBIT
ReSPNSE