680 Synergy Plus – Digital Weight Indicator
64
Visit our website
11.3.3 Avery Weigh-Tronix Stream Format (
wtronix
)
Figure 11-3. Avery Weigh-Tronix Stream Data Format
11.3.4 Mettler Toledo Stream Format (
toledo
)
Figure 11-4. Mettler Toledo Stream Data Format
Space
Polarity:
<+> for positive
"–" for negative
Six digits, right justified, floating decimal,
leading zeros are present
g for Gross
n for Net
<CR><LF>
or
<CR>
lb = pound
kg = kilogram
g = gram
tn = ton (short)
t = ton (metric)
oz = ounce
<space> = none
Space
<SP> <G/N> <POL> <wwwwww> <SP> <UNIT> <TERM>
<STX> <SWA> <SWB> <SWC> <wwwwww> <tttttt> <CR>
STX (02h)
Status Word A
<CR> entered at end
of string.
Status Word B
Status Word C
MUL1 MUL0
Parity
DP2 DP1 DP0 Fixed Zero/Dec. Pt. Location
0 0 0 x 100
(2 fixed zeroes)
0 0 1 x 10
(1 fixed zero)
0 1 0 x 1
(No decimal point)
0 1 1 x 0.1
(1 decimal place)
1 0 0 x 0.01
(2 decimal places)
1 0 1 x 0.001
(3 decimal places)
1 1 0 x 0.0001 (4 decimal places)
1 1 1 x 0.00001 (5 decimal places)
Disp. Div.
MUL1 MUL0 Multiplier
0 1 x 1
1 0 x 2
1 1 x 5
Even parity bit.
Requires EDP Port setup.
Status Word A:
Status Word C: ASCII 20h (space)
Even parity bit:
Requires EDP Port setup.
Status Word B:
0 = Gross Display Mode
1 = Net Display Mode
0 = Positive indicated weight value
1 = Negative indicated weight value
0 = In range
1 = Out of range
0 = Stable
1 = Motion
0 = lb
1 = kg
Even parity bit:
Requires EDP Port
setup.
Six digits, right justified, dummy zeros, decimal
point with no leading zeroes except for immediately
preceding the decimal point. Leading zeroes
transmitted as spaces.
Tare Weight: Six digits, right justified,
dummy zeros, decimal point with no
leading zeroes except for immediately
preceding the decimal point.
Leading zeroes transmitted as spaces.
7
6
5
4
3
2
1
0
DP2
DP1
DP0
1
0
Parity
7
6
5
4
3
2
1
0
1
0
0
0
0
0
0
Parity
7
6
5
4
3
2
1
0
1