680 Synergy Plus – Digital Weight Indicator
72
Visit our website
13.0 Specifications
Power
Line voltage:
120-240 VAC
Frequency:
50-60 Hz
Power consumption:
~2 W (AC) with one 350 Ω load cell, 15 W max
Excitation Voltage
10 VDC bi-polar (± 5 VDC), 8 x 350 Ω or 16 x 700 Ω
load cells
Analog Output (Optional)
Type
Voltage or current output,16-bit resolution
Voltage output
0-5 VDC, 0-10 VDC, ±5 VDC, ±10 VDC
Voltage load resistance
1 KΩ minimum
Current output
0-20 mA, 0-24 mA, 4-20 mA
Current loop resistance 1,000 Ω maximum
Analog Signal Input Range
-0.5 mV/V to +7 mV/V
Analog Signal Sensitivity
Recommended:
1 µV/graduation
A/D Sample Rate
6.25-120 Hz, software selectable
Resolution
Internal:
8,000,000 counts
Display:
1,000,000
System Linearity / PI Rating
Within 0.01% full scale
Digital I/O
Four configurable I/O (5 V logic)
Communication Ports
Two RS-232 (three-wire)
RS-485/422 (five-wire)
Micro USB (device)
Ethernet (10/100)
Status Annunciators
Eight LED annunciators
Display
Seven 0.8'' (20 mm) tall, seven-segment digits
Keys / Buttons
Flat membrane panel, tactile feel (18 buttons plus power)
Temperature Range
Legal:
14–104°F (-10–40°C)
Industrial:
14–122°F (-10–50°C)
Environmental
Intended environment:
Pollution Degree 3
Wet location:
Rated for washdown environments
Recommended use:
Indoor
Dimensions (W x H x D)
11.58 x 8.57 x 4.05'' (29.41 x 21.77 x 10.29 cm)
Weight
6.25 lb (2.84 kg)
Rating / Material
Rating:
IP69K
Material:
AISI 304 Stainless Steel
Warranty
Two-year limited warranty
EMC Immunity
10 V/m
Certifications and Approvals
NTEP
CoC Number 19-021
Accuracy Class: III / IIIL; n
max
: 10 000
UL
File Number: E505539
OIML
Approval Pending
Measurement Canada
Approval AM-6121C
Accuracy Class: III / IIIHD;
n
max
: 10 000
The 680 complies with Part 15 of the FCC Rules. Operation is subject to
the following conditions:
• This device may not cause harmful interference.
• This device must accept any interference received, including
interference that may cause undesired operation.