4.2
MENU A
(key P1) - List of parameters
The following table lists the entries of
menu A
and reports a short description of the parameters that can be adjusted.
Refer to paragraph ADVANCED FEATURES for more details
Auto Reclosing
Timer
Timed closure of the door (only from total or pedestrian opening)
OFF
: disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
HH:MM:SS
: time of persistence in opening position
Photocell
Auto Reclose
Immediate closing after the intervention of the photocell (only from total or pedestrian opening)
OFF:
disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
ON:
the door closes 3 s after the contact between photocell has restored
Motor Brake
Motor Brake operation (for motors with high inertia).
OFF
: disabled
(Suggested for SUPER 3000 FAST)
1:
electronic brake
(Don’t use with SUPER 3000 FAST !)
2:
activation of the contact for an external brake. Active with still motor
3: activation of the contact for an external brake. Active when motor is moving. (By factory for SUPER 3000 FAST and JOLLY FAST)
4:
pre-activation of the contact for an external brake. Active with still motor
5:
pre-activation of the contact for an external brake. Active when motor is moving
Dead Man
“Dead Man” mode. The motor moves only by means of a permanent command
OFF
: disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
ON
: enabled (
WARNING: automatic motions are disabled
)
Condominium
Condominium feature. The commands S.S. and
PED
allow only the opening of the door
OFF
: disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
ON
: enabled (
WARNING: enable the “Automatic Re-Closure” in order to close
)
Photocell Invertion
Photocell intervention modality
OFF
: the door stays still until the obstacle is removed, and then opens completely
ON
: the door opens completely (this feature does not apply in opening).
(By factory for SUPER 3000 FAST and JOLLY FAST)
Photo Test
Functional test of the photocell; it is executed before the door moves
OFF
: disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
ON
: test activated (
WARNING: supply the photocell with power as shown in the scheme
)
Edge Inversion
Modality of operation of the safety edge (sensible edge)
OFF
: the door stops
ON
: the door opens completely (this feature does not apply in opening).
(By factory for SUPER 3000 FAST and JOLLY FAST)
Edge Test
Functional test of the safety edge; it is executed before the door moves
OFF
: disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
ON
: test activated (
WARNING: supply the safety edge with power as specified in the chap. 2.12
)
Pre-Blink
Short flash before the motion of the door
OFF
: disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
ON
: enabled
Area light
Modality of featureing of the auxiliary output for lighting
OFF
: courtesy light.
(By factory for SUPER 3000 FAST and JOLLY FAST)
ON
: zone light (lit-off only when the door is completely closed)
Aux Light Time
Auxiliary light’s switching-off delay for lighting
OFF
: Auxiliary light’s output disabled
HH:MM:SS
: switching-off delay - auxiliary light’s output enabled.
(1 minute - By factory for SUPER 3000 FAST and JOLLY FAST)
Clock
Programmed opening feature
OFF
: disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
ON
: the door opens and stays open until the
OPEN
input is active
Deceleration
Select the deceleration ramp between the normal movement speed and the low speed.
1:
slow deceleration ramp.
(By factory for SUPER 3000 FAST and JOLLY FAST)
10:
Fast deceleration ramp
Encoder
Functioning with encoder (only for motors equipped with a suitable encoder)
OFF
: disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
ON
: enabled (WARNING: the re-programming of the runs is needed)
Sensor level
Level of operation of the “motor still sensor” (with active encoder only)
OFF
: sensor disabled.
(By factory for SUPER 3000 FAST and JOLLY FAST)
NNN : sensor enabled - adjustment of operation’s sensitivity
Sensor Inversion
Modality of operation of the “motor still sensor” (with active encoder only)
OFF
: the door stops
ON
: reverses shortly in opening; opens completely in closing.
(By factory for SUPER 3000 FAST and JOLLY FAST)
EXIT
G
B
MENU A
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
➡
40