G
B
2. CONNECTIONS
1⃣
ANTENNA INPUT
Connect the signal cable of the antenna to the clamp 1 of the
control board.
Connect the ground of the antenna to the clamp 2 of the
control board.
The presence of the metallic parts or humidity in the walls could
have negative influences on the range of the system. We suggest
therefore to not place the receiving antenna and/or transmitters
near big metallic objects, near the floor or on the ground.
2⃣
STEP BY STEP COMMAND
Connect the STEP-BY-STEP BUTTON (S.S.) between the clamps
3 and 4.
ATTENTION: leave it open if not used.
Under the dead man mode the STEP BY STEP BUTTON operates
as
OPEN
.
3⃣
PHOTOCELL INPUT
Connect the NORMALLY CLOSED contact of the photocell
(
PHOTO
) between the clamps 3 and 5 of the control board.
ATTENTION: jumper the inputs if not used.
The operation of the photocells can be modified in the
MENU A
.
4⃣
STOP COMMAND
Connect the NORMALLY CLOSED contact of the
STOP
button
between the clamps 3 and 6 of the control board.
ATTENTION: jumper the inputs if not used.
5⃣
SAFETY EDGE INPUT
Connect the contact NORMALLY CLOSED of the SAFETY
EDGE
between the clamps 3 and 7 of the control board.
ATTENTION: jumper the inputs if not used.
6⃣
CLOSING LIMIT SWITCH INPUT
Connect the NORMALLY CLOSED contact of the CLOSING LIMIT
SWITCH (
L.S.CL.
) between the clamps 3 and 8 of the control
board.
Before activating the motor, make sure that limit switches are
correctly adjusted.
7⃣
OPENING LIMIT SWITCH INPUT
Connect the NORMALLY CLOSED contact of the OPENING LIMIT
SWITCH (
L.S.CL.
) between the clamps 3 and 9 of the control
board.
Before activating the motor, make sure that limit switches are
correctly adjusted.
8⃣
PEDESTRIAN OPENING COMMAND
Connect the PEDESTRIAN OPENING button (
PED
.) between the
clamps 3 and 10 of the control board.
ATTENTION: leave it open if not used
When dead man mode is enabled, the Pedestrian opening button
operates as
CLOSE
.
9⃣
OPEN COMMAND
Connect the
OPEN
button between the clamps 3 and 11 of the
control board.
ATTENTION: leave it open if not used
It is FUNDAMENTAL to connect the electric EARTH to the control board and
the motor in order to obtain the correct operation of the control board and
photocells !
WARNING!! DELTA CONNECTION OF THE MOTOR IS REQUIRED.
For the connection of the motor we recommend to use a screened cables 3 poles + earth 1.5
mm2 (type FD781CY)
NOTE: EDGE, PHOTO and STOP inputs (NC). If they are not used, must be
excluded.
ATTENTION: before starting the automation, make sure that the safety
devices installed are working correctly.
37