Manual CE (SAGOMA _GB)
The display shows "
OFF 31B
":
the machine is out of order
An error occurred in the
temperature control of the
coffee boiler (low temperature)
Check and replace, if
necessary, the temperature
probe in the coffee boiler, the
resistance
The display shows "
OFF 31C
":
the machine is out of order
An error occurred in the
temperature probe of the coffee
boiler
Check and replace the
temperature probe in the coffee
boiler
The display shows "
OFF 33A
":
the machine is out of order
An error occurred in the
temperature control of the
instant boiler (high temperature)
Check and replace, if
necessary, the temperature
probe in the instant boiler, the
resistance and the
correspondent triac on the
power board
The display shows "
OFF 33B
":
the machine is out of order
An error occurred in the
temperature control of the
instant boiler (low temperature)
Check and replace, if
necessary, the temperature
probe in the instant boiler, the
resistance
The display shows "
OFF 33C
":
the machine is out of order
An error occurred in the
temperature probe of the
instant boiler
Check and replace the
temperature probe in the instant
boiler
The display shows "
OFF 50A
":
the machine is out of order
Communication problems
between CPU board and Power
board
Check the connecting cable
and the boards.
Try to load the slave file with
the flash card
Il display mostra "
PLEASE
LOAD THE MASTER
PROGRAM
"
It has not been loaded any
master program in the CPU
board
Ask to Rhea technical service
the correct master file and los
the file master with flash card
into the machine
60/60