Manual CE (SAGOMA_GB)
18.2 Miscellaneous shortcomings
The shortcomings described in this section are not indicated by any message displayed on the
machine.
SYMPTOM PROBABLE
CAUSE
SOLUTION
The machine does not switch
on (no component is powered)
No mains voltage
Wait for the resetting of mains
voltage
The boiler is overheated
Reset the safety thermal switch
boiler. Check the correct
operation and cable of the
thermal probe or the resistance
in the boiler and replace them if
necessary
One general fuse (230V) is
burnt out
Replace it
The safety switch of the door is
faulty
Replace it
The machine does not switch
on (some components are
powered but the display is off)
The fuse on the CPU board (8.5
V) is burnt out
Replace it
The display is badly connected
to the CPU board
Check the correct connection
The machine is on, the
selection starts regularly but
neither water nor ingredients
are dispensed
One of the power fuses (24 V)
on the transformer support is
burnt out
Replace it
61/61