RECO PLC ISP200-R/G2
DeviceNet Master Connection
11-3
DOK-CONTRL-MTS-R0*.2G2-PR01-EN-P
11.3 Status and Diagnostic Displays
With the start of the DNM03 a self-test is started, whereby the yellow RDY
LED lights up after the initialization time (2-3 seconds) after an error-free
test cycle. Otherwise, the RDY LED starts to flash and the program
execution is interrupted. The further meanings of the indicators during the
initialization phase are listed below.
RDY
LED yellow:
Ready
ON:
DPM01 or DPS01 ready for operation
Flashes cyclically:
Bootstrap loader active
Flashes irregularly:
Hardware or system error
OFF:
Hardware defective
RUN
LED green:
RUN (communication)
ON:
Communication runs
Flashes cyclically:
Communication stopped
Flashes irregularly:
Missing or wrong configuration
OFF:
No communication
NET
ON green:
Communication at the bus established
Flashes green:
No communication at the bus
ON red:
Critical connection error
Flashes red:
Time monitoring error
OFF:
No operating voltage, not at the bus
MOD
ON green:
Device works
Flashes green:
Ready for operation
ON red:
Non-correctable error
Flashes red:
Subordinated error
OFF:
No operating voltage
11.4 Technical Data
Supply
Operating voltage:
+5 V ±5 % / 650 mA
Op. voltage DeviceNet interface:
+11 V – +25 V / 55 mA
Interface data
Communication interface:
ISO 11898, max. 500 kbaud, isolated
Diagnostic interfaces:
RS232C, 9600 baud, non-isolated
Operating conditions
Operating temperature:
0 °C - +55 °C
Storage temperature:
-25 °C - +70 °C
Relative humidity:
Max. 75%, condensation to be avoided
Summary of Contents for DURADRIVE SYSTEM200
Page 1: ...Project Planning Manual DOK CONTRL MTS R0 2G2 PR01 EN P SYSTEM200 RECO PLC ISP200 R G2 ...
Page 6: ...IV Contents RECO PLC ISP200 R G2 DOK CONTRL MTS R0 2G2 PR01 EN P ...
Page 26: ...4 6 Technical Data RECO PLC ISP200 R G2 DOK CONTRL MTS R0 2G2 PR01 EN P ...
Page 30: ...5 4 Communication RECO PLC ISP200 R G2 DOK CONTRL MTS R0 2G2 PR01 EN P ...
Page 42: ...6 12 Startup RECO PLC ISP200 R G2 DOK CONTRL MTS R0 2G2 PR01 EN P ...
Page 46: ...7 4 RECO PLC MTS R01 2 RECO PLC ISP200 R G2 DOK CONTRL MTS R0 2G2 PR01 EN P ...
Page 50: ...8 4 RECO PLC MTS R02 2 RECO PLC ISP200 R G2 DOK CONTRL MTS R0 2G2 PR01 EN P ...
Page 54: ...9 4 INTERBUS Master Connection RECO PLC ISP200 R G2 DOK CONTRL MTS R0 2G2 PR01 EN P ...
Page 66: ...12 4 Serial Interfaces RECO PLC ISP200 R G2 DOK CONTRL MTS R0 2G2 PR01 EN P ...
Page 85: ......