RESOLUTE FS with
BiSS
®
Safety
encoder system installation guide and safety manual
5
Original
instructions
Storage and handling
RESOLUTE RESA and REXA are non-contact optical encoders that provide good
immunity against contaminants such as dust, fingerprints and light oils. However, in
harsh environments such as machine tool applications, protection should be provided
to prevent ingress of coolant or oil.
N-heptane
CH
3
(CH
2
)
5
CH
3
Propan-2-ol
CH
3
CHOHCH
3
System
Acetone
CH
3
COCH
3
Chlorinated
Solvents
Readhead only
Methylated
Spirits
Acetone
CH
3
COCH
3
Methylated
Spirits
Chlorinated
Solvents
Ring/scale only
Storage
Operating
Humidity
95% relative humidity (non-condensing)
to IEC 60068-2-78
+80 °C
-20 °C
+80 °C
0 °C
Ring scale
Minimum
bend
radius
RSLA - 250 mm, RTLA30-S – 150 mm,
RTLA30 - 50 mm,
FASTRACK
- 200 mm
RELA -
DO NOT BEND
NOTE:
Ensure self-adhesive tape is on outside of bend
Linear scale