RESOLUTE FS with
BiSS
®
Safety
encoder system installation guide and safety manual
26
Original
instructions
RTLA30 scale and
FASTRACK
carrier installation
During handling or installation of
FASTRACK
suitable gloves should be worn to protect against injury from sharp edges.
2
Thoroughly clean and degrease
the substrate and allow to dry.
For
FASTRACK
location a ledge,
separate straight edge(s) or
dowels can be used.
Check alignment of ledge/separate
straight edge(s) with respect to
axis of motion
(see installation drawing).
1
If required cut
FASTRACK
and scale to length
(separately) using guillotine
(A-9589-0071)
after referring to installation drawing.
Guillotine should be held securely in place,
using a suitable vice or clamping method.
Feed
FASTRACK
or scale through the
guillotine as shown, and place guillotine
press block down onto the
FASTRACK
/scale.
Ensure the block is in the correct orientation
(as shown). Whilst holding the block in place,
in a smooth motion, pull down the lever to cut
through the
FASTRACK
/scale.
Before sticking
FASTRACK
to
the substrate bend the centre
section upwards slightly using
a small pair of pliers.
3
4
Remove backing liner and stick to substrate, locating
against ledge/separate straight edge(s) or dowels.
Ensure complete adhesion to the substrate by
applying firm finger pressure along the length
of the
FASTRACK
from the centre outwards
towards each end using a lint-free cloth
if required.
NOTE:
Allow the
FASTRACK
a minimum
of 20 minutes to adhere before removing
the centre section.
IMPORTANT:
Wear suitable
protective gloves whilst
carrying out this procedure
to avoid risk of cuts.
5
Engage centre section removal tool and with consistent
forward pressure remove centre section.
If the ledge method or similar is used
then the appropriate side panel on
the removal tool
(A-9589-0122)
will need to be removed
as shown.
Ledge
Side panels
DO NOT CUT
FASTRACK
in these
areas
Guillotine
press block