Step 5
Insert screws into the remaining mounting holes.
Rotate the RESA ring, measuring the radial displacement at all
of the screw locations.
Tighten the screw with the lowest radial displacement so that it
matches the average radial displacement, whilst ensuring the
maximum torque specified in the table is not exceeded.
Again, rotate the RESA ring and re-check the radial displacement
at all of the screw locations, tightening the screw with the lowest
radial displacement so that it matches the average.
Repeat this process until the radial displacement at all of the
screw locations is within ±3 µm and that all screw torques are
within the specified range.
Excessive tightening of screws can have a small effect on accuracy.
Please contact your local Renishaw representative for more details.
Diameter
(mm)
Recommended
torque range
(Nm)
≤
115
1.5 - 2.1
150 to 255
0.8 - 1.1
300 to 413
0.5 - 0.7
≥ 417
1.2 - 1.7
Step 4
DO
DS
NOTE:
417, 489 and 550 mm rings
should be taper mounted only.
DO
= Nominal external diameter
DS
= Recommended shaft diameter
to enable interference fit
*
52 mm ‘B’ section ring = 32.033
32.017
Remove the protective film from the surface of the RESA
Clean the mounting faces of shaft and RESA as
‘Storage and handling’ on page 5
NOTES:
Do not lubricate the screws
Do not use a thread locking compound
Ensure that all screws are tightened to 1.6 Nm
Minimum thread engagement is 6 mm
Recommended screw type is M3 × 0.5 and must comply
with: ISO 4762/DIN 912 grade 10.9 minimum/ANSI B18.3.1M
Mounting shaft specifications
DO (mm)
DS (mm)
52*
30.033
30.017
57
37.033
37.017
75
55.039
55.020
100
80.045
80.023
103
80.045
80.023
104
80.045
80.023
115
95.045
95.023
150
130.052
130.027
200
180.052
180.027
206
186.060
186.031
209
186.060
186.031
229
209.060
209.031
255
235.060
235.031
300
280.066
280.034
350
330.073
330.037
413
392.073
392.037
Interference fit method