RESOLUTE FS with
BiSS
®
Safety
encoder system installation guide and safety manual
25
Original
instructions
Dimensions and tolerances in mm
RTLA30 scale and
FASTRACK
carrier installation drawing
RTLA30 scale
(A-9764-xxxx)
FASTRACK
(A-9704-xxxx)
Scale end cover
(Pair A-9589-0058)
18
5
A
Optical centreline
0.75 ±1
Ra 3.2
18 ±0.1
Overall length (L + 12)
Scale length (L)
Measuring length ML = (L
−
10)
2 min - 10 max (gap)
1 min (gap)
‡
0.1 / 100
0.5
F
F = axis of motion
FASTRACK
length (L
−
28)*
0.05 F
F = axis of motion
*
Assumes 1 mm gap between scale and end covers and minimum 2 mm gap between
FASTRACK
and end covers. Dimensions correct for single section of
FASTRACK
. Additional
FASTRACK
sections will require a minimum 2 mm gap
between each section.
NOTE:
Minimum recommended
FASTRACK
length = 100 mm. All dimensions applicable when using side cable outlet version.
†
Only required for sectional installations.
‡
For thermal expansion.
Detail B
35 max
†
B
Spot of Loctite
®
435
™
(2 positions) to secure
axis datum position
Detail A
(with adhesive datum clamp)
2 min
DO NOT CUT
FASTRACK