Maintenance message
Unlike the other fault messages,
the maintenance message can
be acknowledged or reset via the
wireless remote control. This is
due to the fact that it is a purely
informative message.
Proceed as follows to set up the
new maintenance interval.
1. Hold down the Right key for
5 seconds to open the fitter menu.
2. Use the Up and Down keys
to navigate to the maintenance
symbol.
3. Use the Right and Left keys to
change the 0 value to the required
maintenance interval.
4. Confirm the new maintenance
interval by pressing the Enter key.
Fault messages
The fault messages correspond
to the alarm messages which can
also be shown on the unit’s control
board display. To make the alarm
message recognizable, the fault
symbol is also displayed on the
wireless remote control.
Generally speaking, the fault
messages can only be reset on the
display panel of the control board.
The unit must be thoroughly
inspected and the fault reset
following rectification each and
every time.
No changes can be made to the
setpoints in the setup menus while
there is an active fault.
User setup menu
Hold down the Enter key for
3 seconds to open the user setup
menu.
In this menu it is possible to switch
between the wireless remote
control symbols using the Up
and Down keys provided the
corresponding option of “OF” has
been set to a value on the control
board itself. Please read pages 12
and 13 to set these values.
The Left and Right keys can be
used to set these parameter values.
The parameter is confirmed as
a new setpoint using the Enter
key. When this is confirmed, the
remote control switches back to
the symbol and exits the menu.
If you would like to exit the user
setup menu, do not press any
keys on the remote control for
10 seconds.
External heating
Dehumidification
User setup menu symbols
External heating
Dehumidification
External fan
Maintenance interval
Fitter setup menu symbols
Examples of fault messages
Sensor fault
Overly high
pressure level
detected
Maintenance message
NOTE
Do not simply reset the fault
messages without establishing
the cause first.
HP
High priority
LP
SEnS
Abt
AbrH Low priority
Fault priority
General
The wireless remote control
displays the values for humidity
and temperature at all times.
The values only disappear when
a malfunction arises.
Depending on which function is
currently active, one or more of
the symbols appear in the centre
of the display.
Fault priority
In the event that several faults
occur at the same time, only the
fault with the highest priority is
displayed.
Fitter setup menu
Hold down the Right key for
5 seconds to open the fitter setup
menu. At this point it is possible
to access all four menu items. It is
also necessary to set the respective
“OF” option on the control board
to a specific value to enable access.
17