6.7.2.
Modification of the installer-level
parameters
Parameters
p17
to
df
must only be modified by a qualified
professional. To prevent unwanted settings, some parameter settings
can only be changed after the special access code
0012
is
entered.
CAUTION
Modification of the factory settings may be detrimental to
the functioning of the appliance.
1. Press the two keys
f
simultaneously and then key
[+]
until the
symbol
?
flashes on the menu bar.
2. Select the fitter menu using the
key.
c0de
appears on the
display.
3. Use keys
[-]
or
[+]
to input the installer code
0012
.
4. Confirm using key
S
.
p[1
is displayed with
1
flashing.
5. Press the
S
key a second time. The value
80
°C appears and
flashes (for example).
6. Change the value by pressing the
[-]
or
[+]
key. In this example
using key
[-]
to
60
°C.
7. Confirm the value with the
S
key:
p[1
is displayed with
1
flashing.
8. If necessary, set other parameters by selecting them using the
[-]
or
[+]
keys.
9. Press the
>
key 2 times to return to the current operating
mode.
The boiler also returns to operating status if no keys are
pressed for 3 minutes.
6.7.3.
Setting the maximum heat input for central
heating operation
The speed can be changed using parameter
p17
. To do this,
proceed as follows:
T000819-E
3x
2x
CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX
CALORA TOWER GAS 35S EX
6. Commissioning
22/04/2016 - 300026141-001-07
73