THERMOJET
®
G-3700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740151
Rev
03
Date
June 2020
Page
23
of
111
System Exhaust and Relief Valve Connections
The exhaust to flare connection is a 3/4” FNPT spring-loaded check valve rated at 1/2 PSIG.
(0.04 BAR) Do not reduce the connection size. Smaller connection size will reduce the flow of
nitrogen supply through the jet mixer.
This machine is designed to remove
hydrocarbon and water contamination from the
processed oil.
Discharge connection must be made only to
the facility vent and flare network or to a
system specifically designed to safely manage
noxious and / or explosive gasses and
substances present in the oil being purified.
DO NOT BREATH DISCHARGE VAPORS
Outlet Connection
To Flare System
3/4” NPT
Relief Valve Connection
1” NPT
Flare and Relief Valve Connections