Receipt Inspection
Remove all shipping materials and plastic plugs.
Inspect for shipping damage externally and internally (open enclosure door), and report any found
to the manufacturer immediately. It is desirable to take photographs of any damage to
substantiate your claim.
Inspect for completeness of materials and equipment against the packing list and the purchase
order.
Placement of Equipment
After verifying the adequacy and strength of all relevant support surfaces, place the Thermo
Jet
Oil Purifier as close as possible to the oil reservoir in an upright position. See Dimensional
Drawings in the PARTS LIST / DRAWINGS / SCHEMATICS section of this manual for anchor
bolt and equipment clearance dimensions
The ThermoJet Oil Purifier is constructed with lift rings. Ensure that lifting equipment and rigging
is suitable for safely lifting, moving and placing the equipment.
Using standard plant practices secure the ThermoJet Oil Purifier to the installation surface by
bolting the four (4) mounting feet.
NOTICE:
Be sure to leave working space around the system and consider
space requirements for electric heater removal, fully opened access
door, control panel enclosure door, and gauge monitoring.
Do not tip or stand equipment on edge
WARNING
Use suitable transport equipment for lifting and
setting the equipment into place. Ensure that the
equipment is secured prior to and during lifting
and transport. Stand clear of the all equipment
while being maneuvered. Crane and fork truck
operators should be properly trained in there
operation.