![RelaDyne THERMOJET G3700E Series Installation And Operating Manual Download Page 85](http://html1.mh-extra.com/html/reladyne/thermojet-g3700e-series/thermojet-g3700e-series_installation-and-operating-manual_1435626085.webp)
THERMO
JET
®
G-3700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740151
Rev
0
Date
Dec 2014
Page
85
of
111
PID Symbol Legend and Customer Connection Chart
CUSTOMER CONNECTIONS CHART
CONN.
QTY
DESCRIPTION
TYPE / RATING
A
1
OIL SUPPLY INLET
1" FNPT
B
1
OIL RETURN OUTLET
1" FNPT
C
1
NITROGEN SUPPLY INLET
3/8" FNPT
D
1
SAFETY RELIEF OUTLET
1" FNPT
E
1
VENT TO FLARE OUTLET
3/4" FNPT
F
1
PAN DRAIN
3/4" FNPT,
G
1
CONDENSATE DRAIN
1/2" FNPT
EA
1
GROUNDING LUG
14 - 1/0 AWG WIRE SIZE
CHECK VALVE
PRESSURE CONTROL VALVE
PRESS. RELIEF VALVE
JET MIXER
SYMBOL LEGEND
OIL TUBING
OIL PIPING
COUPLING
PUMP
OIL LEVEL CONTROL VALVE
*
SIGHT FLOW INDICATOR
Y-STRAINER