![RelaDyne THERMOJET G3700E Series Installation And Operating Manual Download Page 73](http://html1.mh-extra.com/html/reladyne/thermojet-g3700e-series/thermojet-g3700e-series_installation-and-operating-manual_1435626073.webp)
THERMOJET
®
G-3700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740151
Rev
03
Date
June 2020
Page
73
of
111
Removal From Use, Disposal And Transport
Typical service life for ThermoJet Oil Purifier equipment manufactured by the manufacturer is 20+
years. Once the ThermoJet Oil Purifier is installed and commissioned in an operating
Hydrocarbon Processing Industry (HPI) process unit, its service life generally coincides with the
life of the owners operation of the plant. Disposal methods used should comply with the users
plant policy and guidelines used for disposal of other machinery assets.
If the ThermoJet Oil Purifier has reached the end of its useful working life and a no-repair
decision is made it must be disposed through a licensed scrap or waste disposal facility.
Alternately the machinery may be partially or completely striped for recycling purposes. Prior to
shipment to a recycling facility or disassembly for recycling the following steps should be
performed;
•
All oil must be drained from the separation tank, the oil heater tube, the oil filer housing
and interconnecting piping and tubing.
•
Disconnect all external supply oil connections. Take care to avoid spills. For oil supply
and return connection locations reference the
INSTALATION
section of this manual.
•
Remove and drain all oil supply, oil return and flare connection tubing, pipe and
hardware.
•
Remove all oil filters. Dispose of elements in accordance with all regulatory requirements
in force at the time of equipment disposition. Consult you company environmental
protection or plant safety department for guidance.
•
Turn off and disconnect supply nitrogen connection. For nitrogen supply connection
locations reference the
INSTALATION
section of this manual.
In case of oil spillage, the user or other
responsible body must ensure appropriate
cleanup and decontamination is carried out.
NOTICE:
Recycle all drained oils and oil filters.
Ensure that the supply nitrogen piping is OFF
prior to disconnecting. The source should be
equipped with a plugged block valve to prevent
inadvertent future N2 blast.
WARNING