City Series
|
13
installation
Caution Requirements
The top, back and sides of the ireplace are deined by
standoffs. The metal ends of the standoff may
NOT
be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this ireplace and vent
system be installed only in accordance with these instructions.
Clearances CV40E (single sided)
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related ires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
ireplace and vent system be installed only in accordance with these instructions.
Note: CV40E (single sided unit) clearances listed on this page - for CB40E (3 sided) see next page.
Clearance: single sided
Dimension
Measured From:
A: Mantel Height (min.)
**
Top of Fireplace Opening
B1:From Floor
25-9/16" (649mm)
Top of Fireplace Opening
B2: Opening Height
15-1/16" (383mm)
Bottom/Top of Fireplace Opening
C: Sidewall (on one side)
8-1/2" (216mm)
Side of Fireplace Opening
D: Mantel Depth (max.)
**
E: Alcove Width
84" (2134mm)
Sidewall to Sidewall (Minimum)
F: Alcove Depth
36" (914mm)
Front to Unit (Maximum)
G: Ceiling
(in front of ireplace)
37-1/2" (953mm)
Top of Fireplace Opening
H: Convection Air Outlet
*
Top of Enclosure
J: Convection Air Outlet Opening Ofset
0-3" (76mm)
Max. ofset from top of chase enclosure
K: Chase Enclosure (Min.)
63" (1600mm)
From base of unit/loor
Hearth
0"
No hearth required
**
See mantel clearances chart in this manual.
Flue Clearances to Combustibles
Horizontal - Top
3"
Horiztonal - Side
2"
Horiztonal - Bottom
2"
Vertical
2"
Passing through wall/
f l o o r / c e i l i n g - w h e n
irestop is used.
1-1/2"
Alcove
E
F
D
A
C
B
1
G
B
2
J
H
K
The
HeatWave
Duct Kit has differ-
ent clearance and framing require-
ments, check the
HeatWave
manual
for details.
CV40E- Single sided
*
A minimum of 120 square
inches of open area, not
lower than 3" from top of
enclosure, required for all
installations
Summary of Contents for City Series CB40E-LP
Page 86: ...86 City Series parts list 7 8 9 2 1 3 6 4 5 12 17 27 19 20 18 22 6a 26 24 23 25 11 ...
Page 89: ...City Series 89 parts list 16 12 22 21 18 20 19 9 26 25 8 11 26 16 16 6 23 5A 27 17 16 ...
Page 90: ...90 City Series notes ...
Page 95: ......
Page 96: ...96 City Series notes ...
Page 97: ...City Series 97 notes ...
Page 98: ...98 City Series notes ...
Page 99: ......