City Series
|
83
maintenance
Valve Replacement
Important:
Always shut off gas supply/120 volt power prior to servicing the
gas valve.
1. Turn off unit and allow to cool to room temperature.
2. Remove outer enamel or steel panels—see instructions in the panel removal
section in this manual
3. Remove outer safety glass panels and inner panels (irebox glass)–see
instructions in this manual.
4. Remove all media and logs (if installed) — set aside.
5. Remove inner base panel.
7. Remove 16 screws in locations shown below.
8. Lift valve tray by out partially and disconnect lexible gas connection on the
valve inlet side, remove valve tray- replace with new valve tray.
9. Reverse steps 6-1 to complete.
Inner base panel
Remove 16 screws securing valve tray
CB40E shown
6. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide burner
to the left away from the oriice and lift out.
front
screw locations
back screw locations