City Series
|
47
installation
Notes:
1. Liner sections should be continuous without any
joints or seams.
2. Only Flex pipe purchased from Regency
®
may be
used for Flex installations
3. Horizontal vent must be supported every 3 feet.
4. Regency
®
Direct Vent System (Flex) is only approved
for horizontal terminations.
5. Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer
runs are required, rigid pipe must be used.
Horizontal Terminations
Flex Vent 4" x 6-7/8
"
These venting systems, in combination with the CV40E/CB40E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock
Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination
Locations" section.
Regency
®
Direct Vent (Flex) System Termination Kits includes all the parts needed to install the CV40E/CB40E using a lexible vent.
NOTE: A minimum of 1' (305mm) vertical off the top of the unit is required before any horizontal runs can start.
FPI Kit #
Length
Contains:
#946-513
2 Feet
1.
6-7/8” lexible outer liner (Kit length)
2.
4” lexible inner liner (Kit length)
3.
spring spacers
4.
thimble
5.
AstroCap
termination cap
6.
screws
7.
tube of Mill Pac
8.
plated screws
9.
S.S. screws #8 x 1-1/2” drill point
#946-515
4 Feet
#946-516
10 Feet
Summary of Contents for City Series CB40E-LP
Page 86: ...86 City Series parts list 7 8 9 2 1 3 6 4 5 12 17 27 19 20 18 22 6a 26 24 23 25 11 ...
Page 89: ...City Series 89 parts list 16 12 22 21 18 20 19 9 26 25 8 11 26 16 16 6 23 5A 27 17 16 ...
Page 90: ...90 City Series notes ...
Page 95: ......
Page 96: ...96 City Series notes ...
Page 97: ...City Series 97 notes ...
Page 98: ...98 City Series notes ...
Page 99: ......