installation
Unit Assembly Prior To installation
The nailing strips must be correctly positioned and attached before unit is
slid into position.
Nailing Strips-Combustible Finishing
The nailing strips come attached to the unit. There is one plate on each side
and one on the top. The top and side nailing strips are secured to the framing.
Installing Access Panel
The unit is equipped with a removable access panel for pre-finish installation
of optional components. This panel is located on the lower front face. Access
to the gas connection is easier with the panel removed.
1. Remove four screws to remove access panel.
2. Install any optional components with access panel removed.
3. To reinstall the access panel, line up the two upper tabs and secure with
four screws.
Combustible Finishing Unit Assembly/ Finishing/ Mantel Clea Mantel Leg Clearances
Nailing Strips
(DO NOT REMOVE NAILING STRIPS
WHEN USING COMBUSTIBLE FINISHING)
4 screws
IMPOR
TANT
• The framing depth measurement is noted with the nailing
strips set as far forward on the firebox as possible. The
nailing strips can be adjusted up to 38 mm to allow for vary-
ing thickness of non combustible material & wall finishes.
NO
TE
• The access panel is no longer usable/accessible once facing material
is installed.