Greenfire® GF1500L-2 Gas Fireplace
| 25
installation
Description
Simpson
Direct Vent Pro
®
Attic Insulation Shield
305 mm
58DVA-IS*
High Wind Vertical Cap
58DVA-VCH
High Wind Horizontal Cap
N/A
Horizontal Square Termination Cap
N/A
Vertical Termination Cap
N/A
Storm Collar
58DVA-SC
Restrictor Disk
N/A
Colinear Flex Connectors
N/A
Adjustable Flashing
Flat - 26.57
0
58DVA-F6
Adjustable Flashing
26.57
0
-45
0
58DVA-F12
Vinyl Siding Standoff
58DVA-VSS
Vinyl Siding Shield Plate
N/A
Snorkel Termination
356 mm
58DVA-SNK14
Snorkel Termination
914 mm
58DVA-SNK36*
Basic Horizontal Termination Kit (A
)
N/A
Horizontal Termination Kit (B)
58DVA-KHA
Vertical Termination Kit
58DVA-VHA
FPI
946-604/P
Simpson Direct Vent or Astro Cap -Vent Guard (Optional)
946-623/P
AstroCap XL Horizontal Cap
770-994
Rigid Pipe Adaptor (Must use with all rigid piping)
946-625
Vinyl Siding Standoff - AstroCap XL
Offset Pipe Selection:
Use this table to determine offset pipe lengths.
Pipe Length
(L)
127 mm
x
203 mm
v
enting
For specific instructions on venting components - visit the
manufacturers website listed below.
Run (X)
Rise (Y)
0
mm
144
mm
389
mm
Simpson Direct Vent Pro: www.duravent.com
152
mm
224
mm
468
mm
229
mm
278
m
m
522
mm
305
mm
330
mm
576
mm
610
mm
697
mm
789
mm
Note:
Horizontal runs of vent must be level, or have a
6 mm
rise for every
305 mm
of run towards the termination.
Never allow the vent to run downward - this could cause high
temperatures and may present a possible fire hazard.
914
mm
757
mm
1002
mm
1219
mm
972
mm
1216
mm
* Not available from Regency