48 |
Greenfire® GF1500L-2 Gas Fireplace
installation
GF1500
07 february 22
3
919-592a
OPTIONAL FAN KIT INSTALLATION
FAN DUCT EXTENSION KIT
In order to use the fan extension duct kit, you must have
fan kit. This kit allows you to extend the fan duct to 9m.
1. Attach the connecting collar to the duct that came with the duct kit.
Use the screws provided.
2. Attach the 4.5m duct within this kit to the connecting collar on the opposite
end with the screws provided. Extend the flex to the desired length.
WIRING DIAGRAM
Caution: Ensure that the wires do not touch any hot surfaces
and are away from sharp edges.
Alternate Switches: May use the following. Check with local authorities and electrician.
CLIPSAL 203 2E45 OUD - Dimmer
CLIPSAL 2031 VF3CSF - 3 Speed
CAUTION: Label all wires prior to dis-
connection when servicing controls.
Wiring errors can cause improper and
dangerous operation
ON/OFF Switch
Wire
Brown
Blue
Earth
Earth
240V-50Hz
Brown (Hot)
Blue (Neutral)
(Earth)
Fan
Blue-Neutral Brown-High Red-Low
Green
Heat Zone Unit