City Series ACB40E
|
67
installation
920-217
03.12.20
2
CITY SERIES
15. Reinstall pilot cap and pilot retainer clip.
16. Prior to installing burner—adjust aerations settings:
• 7 mm for Propane
• Fully open for ULPG
Reinstall burner (see Step 13).
17. Ensure the pilot light is in the correct orientation to the Burner. Recon-
nect the gas and electrical supply to the appliance. Start the appliance.
(see section on Lighting Instructions) Ensure that pilot and burner igni-
tion is completed without delay. Check both your inlet and outlet pres-
sures at full load. With a soapy solution, leak test the entire system.
Verify both the correct flame and pilot appearance.
18. See Gas Pipe Pressure Testing in manual.
13. Remove pilot retainer clip with pliers and pull off the pilot cap to expose
the pilot orifice.
14. Unscrew the pilot orifice with the allen key; then replace with the LPG
pilot orifice and the pilot cap, provided in the kit.
Installer Notice:
These instructions must be left
with the appliance
.
Pilot retainer clip
12. Remove burner orifice with a 9.5mm spanner. Use another wrench to hold
on to the elbow behind the orifice. Discard orifice. Reinstall new burner
orifice LP stamped #53 (or #54 ULPG) and tighten.
Burner Orifice
Location
CV40E shown
11. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide
burner to the left away from the orifice and lift out.
front
screw locations
back screw locations
PROPANE SYSTEM DATA
Min. Supply Pressure
2.75 kPa
Manifold Pressure High
2.60 kPa
Manifold Pressure Low
0.70 kPa
Orifice Size
#53 DMS
Maximum Input
30 MJ/h
Minimum Input
16.0 MJ/h
ULPG SYSTEM DATA
Min. Supply Pressure
2.75 kPa
Manifold Pressure High
2.60 kPa
Manifold Pressure Low
0.63 kPa
Orifice Size
#54 DMS
Maximum Input
24 MJ/h
Minimum Input
11.7 MJ/h