38
|
City Series ACB40E
installation
1. Frame in the enclosure for the unit with framing material.
Note:
When constructing the framed opening ensure there is access to
install the gas lines,electrical. Also the wiring harness must be wall mounted
using the receptacle provided with the appliance. The wiring harness will
be located on the right hand side of the appliance if facing the unit from the
front. This must be done prior to any finishing.
2. For exterior walls, insulate the enclosure to the same degree as the rest of
the house, apply vapour barrier and plasterboard, as per local installation
codes. (Do not insulate the fireplace itself).
WARNING:
Failure to insulate and add vapor barriers to the inside of the
exterior wall will result in operational and performance problems including, but
not limited to: excessive condensation on glass doors, poor flame package,
carbon, blue flames etc. These are not product related issues.
Note that in all applications while there is a zero clearance to combustibles
to the unit, all clearances to combustibles from the flueing inside the chase
still applies. Please see flueing clearances in the specific product manual.
3. To ensure the chase is sealed from the outside wall into the room, all
joints on the facing wall
MUST
be sealed, mudded, and taped to finish.
Note that in all applications while there is a zero clearance to combustibles
to the unit, all clearances to combustibles from the flueing inside the chase
still applies. Please see flueing clearances in the specific product manual.
4. Combustible material (plasterboard,wood,wood panels, etc.) may be
brought up to this appliance (top,bottom and sides)
5. Ensure that the material being used does not encroach anywhere in the
area of the glass. This would cause dangerous operating conditions.
6. This appliance comes with a 13mm lip at top, sides and bottom to hide the
ends of the plasterboard. The 13mm side and bottom, front and bottom side
lips supplied with the appliance can alternatively be removed and replaced
with J Style Trim or Metal Corner Bead purchased at your local hardware
store to cover cut/exposed edges of the combustible facing material or
any other finishing materials being used. Six (6) screws secure the bot-
tom front lip. Two (2) secure the bottom side lips and 2 secure each side
if deciding to remove these. These will be hidden so the outer panels (if
installed) will need to be removed to access the screws. See outer panel
removal in this manual.
7. This appliance can also be recessed (using combustible materials) with
a hearth in front of the appliance. This can also extend to the top. See
below for details.
Framing and Finishing Inset Installations
Extended Finish ACB40E (Walls Closed Off at Either End)
Do not place any materials any-
where glass is located.
13 mm
Lip
2134 mm
min.
216 mm
on one side
383 mm
Walls closed off at either end
**Combustible material
The sides can extend out as shown using combustible materials. The opening
must be a minimum of 2134 mm wide and have a minimum of
216mm on one side of the fireplace, if choosing to offset the installation
**Combustible material may extend a minimum of 13mm and to a maximum of
130mm from the Front top. See mantle clearance chart for details.
The base and side (with smaller glass) have no limit when it comes to how
far the combustible material may extend out from the appliance. Ensure
that no material encroaches anywhere in the area of the glass as these are
defined by the finishing lip above, below and to the sides of this appliance.
Do not place any materials
anywhere glass is located.
Note : an offset screwdriver is provided with the appliance for ease of
removal/installation of the lip
removable trim/
finishing lip
finishing lip
removable trim/
finishing lip