City Series ACB40E
|
43
installation
Flue restriction is required for certain flueing installations, see the diagrams in the "Flueing
Arrangements" section to determine if they are required for your installation.
The Flue Restrictor plate is packed in the instruction manual package.
To set the flue restriction as indicated in the flueing arrangements diagrams, refer to the following instructions;
1.
Remove the safety glass and firebox glass - see instructions in this manual.
2.
Remove the screws that hold the flue restrictor plate in place (see Diagram 1)
3.
Adjust the flue restrictor plate to the required flue restrictor position as per the diagrams shown.
4.
Once the flue restrictor plate is in the required position, secure with screws.
Flue Restrictor Position
Flue Restrictor Positions
Flue restrictor location - inside top of firebox
Diagram 1
Screw
locations
51mm
44mm
38mm
Set 0 (Full open) Factory set
Set 1 (Vent restrictor at 51mm)
Set 2 (Vent restrictor at 44mm)
Set 3 (Vent restrictor at 38mm)