City Series ACB40E
|
63
installation
Note:
Ensure that the front glass is centered and evenly spaced with side glass
(3 sided unit) - open to release glass clamps to remove from surface of glass.
ACB40E shown
Handle front panel with supplied vacuum clamps
Open clamps
prior to plac-
ing front glass
panel
5. Ensure all 7 front clamps are in the open position to allow clearance for
the glass.
6. Lift up the front panel using the supplied vacuum clamps and position into
the lower front channel–ensure the front panel is accurately centered—with
the front panel in position—secure in place by closing the 3 lower clamps
and 4 upper clamps.
Open clamps to
release pressure on
the springs
Press glass vacuum clamps in open position firmly onto surface of glass. Bring
handles together to close.
Open
Closed
7.
For 3 sided and corner units only
: Return to the side panel(s), and release
the upper and lower clamps. The springs will release and push the glass
side panel forward slightly—this will create a seal between the front and
side panels. When the junction between the front and side glass panels is
sealed, close the clamps to secure the side panel(s) in place.
8. To remove the glass panels—always remove the side panel(s) (for 3 sided
units) before removing the front panel.
9. Reverse steps to remove glass.