![Reechcraft PowerPole Operators Safety Manual Download Page 30](http://html1.mh-extra.com/html/reechcraft/powerpole/powerpole_operators-safety-manual_1430917030.webp)
30
secti
On
POwER SYSTEM INSTALLATION
5
1. Installation of the electrical system should only be carried out by
a competent person. Installing electrical components on the system
incorrectly could lead to personal injury or death. Examine the
worksite completely, locating any hazards or conditions such as
standing water, sharp objects, high traffic areas, etc.
2. Important: Before installing any electrical cords, be sure all
equipment has been thoroughly examined for proper function and
that no cuts, breaks, or damage of any kind exists with the electrical
supply cords or the electrical cords on the drills. If any electrical lines
are found to be damaged or have excessive wear, discard
immediately and use new equipment.
3. The PowerPole System should only be used with electrical
power drills that have been tested and recommended for use by
ReechCraft or your local dealer. Refer to (Fig. 5.1) for drill and
electrical cord requirements.
4. Assemble the supplied 9.5 mm (3/8 in) driver to the drill. Important:
Only use the driver supplied with the system or equivalent.
POWER SYSTEM INSTALLATION
DRIVER INSTALLATION
Fig. 5.1
PULL-OUT FORCE FOR V-BRACE TIE BRACKET
No Load Speed
(High Speed for ½ Rated Load)
0-1500 RPM (0-3000 RPM)
Output Power
600 W – 700 W
Input Power
850 W – 1050 W
Maximum Operating Speed
@ Rated Load (@ ½ Rated Load)
0-950 RPM (0-1270 RPM)
Maximum Drill Size
1/2 in. (13mm)
Collar Size
1.68 in. -1.75 in. (42.5mm -44.5 mm)
Chuck Type Normal Operation
Keyed Only (Keyless for Setup Only)
Electrical Cord Rating
15 A Lead with 10 A Socket and Plug
Fig. 5.2
Summary of Contents for PowerPole
Page 1: ...Operator s Safety Manual www reechcraft com powerpole P N 4026579...
Page 8: ...8 Section 1 GENERAL SYSTEM INFORMATION CLIMBING UNIT WITH PLATFORM SUPPORTS Fig 1 1 Fig 1 2...
Page 42: ...42 Section TRANSPORT STORAGE AND MAINTENANCE 7 inspection and Maintenance Logs...
Page 48: ...Reechcraft Inc 845 34th St N Fargo ND 58102 888 600 6160 www reechcraft com PowerPole...