Managing Hardware with CLI Commands
Determining Operating Status
5-13
Table 5-12 lists the MIC types.
Table 5-13 describes the output fields for the
show hardware
command (in any mode) with the
detail
keyword; fields are listed in alphabetical order. This command displays information only for those units
that are installed in the chassis, and in most cases, displays only the fields that are applicable to the type of
MIC.
Table 5-12
MIC Types
MIC Type
Description
fe-12-port
• Copper FE MIC
• Optical FE MIC
ge-2-port
• Copper GE MIC
• Optical GE MIC
Table 5-13
Output Fields for the show hardware Command with the detail Keyword
Field
Description
Active Alarms
1
Alarm conditions for this unit:
• None—No alarm conditions exist.
•
condition
—Alarm condition is in effect.
For a complete list of conditions that can cause an alarm, see Appendix B, “Alarms and Probable Causes.”
ALRM LED
State of the ALRM LED. Applicable only to the circuit board controller functions (slot 1):
• Red—A critical or major alarm is active.
• Yellow—A minor alarm is active.
• Off—No alarm is active.
Card Status
• HW detected—Circuit board is detected and being initialized.
• HW failure—Circuit board has experienced a failure.
• HW initialized—Circuit board is initialized and ready.
Chass Entitlement
SE100—This MIC is intended for the SmartEdge 100 chassis only.
Chassis Type
SE100—Circuit board is installed in a SmartEdge 100 chassis.
CLEI Code
Common Language Equipment Identifier (CLEI) code for this SFP optical transceiver; blank if not
applicable for this transceiver.
Connector Type
MIC port connector:
• Copper—RJ-45 connector.
• Optical—SFP optical transceiver (LC) connector.
CPLD Version
n
—Version of the complex programmable logic device (CPLD) on the MIC.
EEPROM id/ver
nnnn
/
n
—Version of the unit EEPROM.
Fan(s) Status
• Failed—At least one fan is not working.
• Normal—All fans are working.
Fan
n
Status of fans 1 to 5—RPM
Hardware Rev
n
—Hardware revision level for this unit. Applicable only to the circuit board controller functions (slot 1).
IPPA and EPPA memory
nnn
MB—Size of ingress and egress PPA memory. Applicable only to the I/O carrier card functions (slot 2).
MAC Address
nn:nn:nn:nn:nn:nn
—Medium access control (MAC) address of the system; displayed only for the circuit
board controller functions.
Summary of Contents for SmartEdge 100
Page 4: ......
Page 8: ...viii SmartEdge 100 Router Hardware Guide...
Page 14: ...Ordering Documentation xiv SmartEdge 100 Router Hardware Guide...
Page 52: ...Connecting and Routing the Cables 4 18 SmartEdge 100 Router Hardware Guide...
Page 72: ...Obtaining Assistance 5 20 SmartEdge 100 Router Hardware Guide...
Page 90: ...FE and GE MIC and Native Port Cables A 6 SmartEdge 100 Router Hardware Guide...
Page 94: ...FE and GE Port Alarms B 4 SmartEdge 100 Router Hardware Guide...