Managing Hardware with CLI Commands
5-10
SmartEdge 100 Router Hardware Guide
Values for CLI Input Arguments
Table 5-8 lists the values for the input arguments in the CLI commands. Values for input arguments that are
shown in bold must be entered in the specified format.
Values for CLI Output Fields
Table 5-9 describes the output fields for the
show chassis
command (in any mode).
Table 5-8
Values for CLI Input Arguments
Argument
Range of Values/Description
Restrictions
port
1 to 26.
The Ethernet management port is always port 1 in
slot 1.
Native ports are always ports 1 and 2 in slot 2.
MIC ports range from 3 to 14 in the left MIC slot
and 15 to 26 in the right MIC slot. For each type of
MIC, see Table 5-12 on page 5-13 for the range of
ports.
port-type
ethernet
—FE or GE port (any version).
slot
1
—Slot in which the Ethernet management port is configured.
2
—Slot for all native and MIC ports.
Note
The following notes apply to the flags displayed by the
show chassis
command:
•
The SmartEdge 100 router does not display the following flags: B, C, G, M, N, S, U, W, and X.
•
D—The default traffic card processes packets sent to it from the controller. For a description of
the functions of the default traffic card, see the “Card, Port, and Channel Operations” chapter in
the
Ports, Circuits, and Tunnels Operations Guide
for the SmartEdge OS.
•
H—The I/O carrier card is administratively shut down with the
shutdown
command (in card
configuration mode).
•
O—The I/O carrier card is placed in the ODD state with the
on-demand diagnostic
command
(in card configuration mode).
•
The I/O carrier card is ready (R flag) when the it has been initialized and the code for the PPAs
has been downloaded; it is up (U flag) when the PPAs on the I/O carrier card are registered with
the requisite NetBSD process.
Table 5-9
Output Fields for the show chassis Command
Field
Description
Current platform is
Chassis type—SE100—SmartEdge 100 router.
Slot
slot
—Slot number for this unit.
Configured type
Slot is configured for:
• carrier—I/O carrier card functions on the circuit board; always reported for slot 2.
• xcrp—Controller functions on the circuit board; always reported for slot 1.
Installed type
Slot always has a card installed:
• carrier—Traffic card functions on the circuit board; always reported for slot 2.
• xcrp—Controller functions on the circuit board; always reported for slot 1.
Summary of Contents for SmartEdge 100
Page 4: ......
Page 8: ...viii SmartEdge 100 Router Hardware Guide...
Page 14: ...Ordering Documentation xiv SmartEdge 100 Router Hardware Guide...
Page 52: ...Connecting and Routing the Cables 4 18 SmartEdge 100 Router Hardware Guide...
Page 72: ...Obtaining Assistance 5 20 SmartEdge 100 Router Hardware Guide...
Page 90: ...FE and GE MIC and Native Port Cables A 6 SmartEdge 100 Router Hardware Guide...