Alarms and Probable Causes
B-1
A p p e n d i x B
Alarms and Probable Causes
This appendix describes alarm conditions and probable causes for the SmartEdge
®
100 chassis and its
components, including Fast Ethernet (FE) and Gigabit Ethernet (GE) media interface cards (MICs) in the
following sections:
•
•
Circuit Board Alarms—Controller Functions
•
Circuit Board Alarms—I/O Carrier Card Functions
•
•
Chassis Alarms
Table B-1 lists supported alarms for the chassis and system, as a whole.
Note
The term, GE, applies to any GE native port or MIC that supports a port speed of 1 Gbps or greater;
unless explicitly stated, the speed of any GE port is 1 Gbps.
Table B-1
Chassis Alarms
Description
Severity
Probable Cause
Service Affecting
Chassis power failure—Side A
Minor
PowerProblem
No
Fan unit failure
Minor
CoolingFanFailure
No
Local alarm cutoff activated
Minor
OperationNotification
No
Multiple fan failure
Major
ReplaceableUnitProblem
Yes
Power supply output fail
Minor
ReplaceableUnitProblem
Yes
Remote alarm cutoff activated
Minor
OperationNotification
No