11-CLEANING AND MAINTENANCE
64
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel whose technical expertise
includes combustion and electricity.
It is recommended to perform this routine maintenance annually (with a scheduled service contract), which focuses on a visual and
functional verification of the internal components. The following is a summary of the necessary checks and/or maintenance for the
product to work correctly.
• Gear motor
• Smoke expulsion fan
• Smoke probe
• Start-up spark plug
• Automatic resettable pellet/water thermostat
• Room/water probe
• Motherboard
• Panel - motherboard protection fuses
• Cabling
PARTS/INTERVAL
2-3 DAYS
EVERY WEEK
15 DAYS
60-90 DAYS
EVERY SEASON
Clean the brazier.*
·
Clean the ash collection compartment
with a vacuum cleaner
·
Clean the ash pan
·
Clean the hearth door and glass
·
Clean the turbulators
·
Clean the lower ash pan
·
Clean the "T" exhaust fittings (outside
the boiler)
·
Clean the exchangers and remove ash
and incrustations
·
Clean the smoke fitting
·
Circulation pump inspection
·
Hydraulic leaks inspection
·
Door gasket inspection
·
Start-up spark plug inspection
·