11-CLEANING AND MAINTENANCE
63
Technical Dept. - All rights reserved - Reproduction is prohibited
CLEANING THE SMOKE FAN COMPARTMENT
Remove the four screws that keep the plug fastened on the rear part of the stove and remove any ash deposited on the smoke fan with
a vacuum cleaner.
Check the seal of the ceramic fibre gasket on the plug and replace it if necessary.
CLEANING THE SMOKE EXHAUST SYSTEM AND GENERAL CHECKS
Clean the smoke extractor system, especially around the “T” joints, elbows and any horizontal sections of the smoke duct.
For information on periodically cleaning the flue, contact a skilled chimney sweep.
Check the seal of the ceramic fibre gaskets on the door of the stove. If necessary, order new replacement seals from the retailer or contact
an authorized service centre to carry out this task.
ATTENTION:
The frequency with which the smoke exhaust must be cleaned depends on the use of the boiler and the type of
installation.
We recommend contacting an authorised service centre for end-of-season maintenance and cleaning as the above-
mentioned operations will be performed together with a general inspection of the components.
END-OF-SEASON SHUTDOWN
At the end of season, before shutting down the boiler, we recommend completely removing pellets from the hopper with the use of a
vacuum cleaner with an extension.
The service fuse may have to be replaced if the control panel display does not go on when the product is re-started upon pressing the main
switch on the rear of the boiler.
On the rear of the boiler there is a fuse compartment which is located underneath the supply socket. Use a screwdriver to open the fuse
compartment and if necessary replace them (3.15 A delayed).