8-MENU ITEMS AND OPERATION
43
Technical Dept. - All rights reserved - Reproduction is prohibited
• Modify the % with the + - keys.
• Press "menu" to confirm and "esc" to exit
k - Smoke rpm % ventilation
If the installation presents difficulties for smoke evacuation (no draught or no pressure in the duct), the smoke and ash expulsion speed
can be increased. This change resolves all the potential problems related to pellets clogging in the brazier and deposits forming at the
bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ashes. The values available are from -30% to +50%
with variations of 10 percentage points at a time. The variation in negative can be used in case the flame is too low
To change the parameter act as follows:
• Press the “menu” button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "Smoke rpm variation" using the arrows.
• Press "menu" to confirm.
• Modify the % with the + - keys.
• Press "menu" to confirm and "esc" to exit
l - Maximum power
It allows to set the maximum flame limit at which the stove can operate to reach the set temperature target.
To change the power act as follows:
• Press the “menu” button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "Maximum power" using the arrows.
• Press "menu" to confirm.
• Change the power from 01 to 05 with the + - keys
• Press "menu" to confirm and "esc" to exit
m - Components test
It can only be carried out with the stove switched off, it allows to select the components to be tested:
• Spark plug
: it is turned on for a fixed time of 1 minute during which the panel displays the countdown seconds.
• Feed screw
: it is powered for a fixed time of 1 minute during which the panel displays the countdown seconds.
• Extractor
: it is activated at 2500 rpm for a fixed time of 1 minute during which the panel displays the countdown seconds.
• Exchanger
: it allows to carry out the test in V5 for a fixed time of 1 minute during which the panel displays the countdown seconds.
• Pump
: it is activated for a fixed time of 10 seconds during which the panel displays the countdown.
• 3 way
: the 3 way valve is activated for a fixed time of 1 minute during which the panel displays the countdown seconds.
To activate the "Components test" function (only when the stove is switched off) act as follows:
• Press the “menu” button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "Components test" using the arrows.
• Press "menu" to confirm.
• Select the test to be performed with the + - keys
• Press "menu" to confirm and "esc" to exit