11-CLEANING AND MAINTENANCE
61
Technical Dept. - All rights reserved - Reproduction is prohibited
CLEAN THE EXCHANGER AND THE UNDERGRATE SPACE EVERY 2/3 DAYS.
Cleaning the exchanger and the undergrate space is a simple operation but very important for always maintaining performance as
declared.
Therefore we recommend cleaning the internal exchanger every 2-3 days, performing these simple operations in sequence:
•
Activate the “CLEANING”
function – when the boiler is switched of press - menu, select“Settings”, with the <> arrows select
“Cleaning”, confirm with “Menu”, activate cleaning “ON” by pressing the +- keys. This procedure activates the smoke extraction fan on
maximum power to expel the soot that is dislodged when the exchanger is cleaned.
•
Clean the pipe unit
– Using the cold handle supplied (the cold handle hangs inside the stove door - fig.2) shake vigorously the
rods placed under the cover 5-6 times. This will remove any soot that has deposited on the exchanger smoke ducts during normal
stove operation.
•
Disable the "CLEANING" function
- this function is automatically disabled after two minutes. If one needs to stop this function in
advance press the "Esc" key.
•
Clean the smoke conveyor compartment (fig.3) -
The boiler is fitted with a removable ash pan designed to collect any soot and
ash build-up.
• Once cleaning is complete close the cover and ash pan.
If such cleaning is not done every 2-3 days the stove could go into alarm caused by ash clogging after several hours
of operation.