8-MENU ITEMS AND OPERATION
39
Technical Dept. - All rights reserved - Reproduction is prohibited
SETTINGS MENU
The SETTINGS menu allows to act on the stove operating mode:
a. Language.
b. Cleaning (displayed only when the stove is switched off).
c. Feed screw loading (displayed only when the stove is switched off).
d. Tones.
e. External thermostat (activation).
f. Auto Eco (activation).
g. Eco-Shutdown T (default 10 minutes).
h. pump on T (default 50°C).
i. Auxiliary boiler (default deactivated).
j. Pellet recipe.
k. Smoke rpm % ventilation.
l. Maximum power (1-5 - default 5).
m. Components test (displayed only when the stove is switched off)
n. "Chimney sweep" function (activated only when the stove is switched on, for field emissions test).
o. System configuration.
p. Season.
q. Technical menu.
NOTE: Some of the items listed above cannot be activated in certain "system configurations".
a - Language
To select the language act as follows:
• Press the “menu” button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "language" using the arrows.
• Press "menu" to confirm.
• With the + - keys select the language of interest (IT/EN/DE/FR/ES/NL/PL/DA)
• Press "menu" to confirm and "esc" to exit.
b - Cleaning
To select "Cleaning" (only when the stove is switched off) act as follows:
• Press the “menu” button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "Cleaning" using the arrows.
• Press "menu" to confirm.
• Select "On" with the + - keys.
• Press "menu" to confirm and "esc" to exit.
c - Feed screw loading
Allows to fill the pellets loading system. It can only be activated with the stove switched off, it displays an 180" countdown after which the
feed screw stops automatically, as when exiting the menu.
To select "Feed screw loading" (only when the stove is switched off) act as follows:
• Press the “menu” button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "Feed screw loading" using the arrows.