red
COMPACT 24 BOILER
Chapter
9
USE AND MAINTENANCE MANUAL
page
48
Programming and settings
Technical dept. - All rights reserved - Reproduction prohibited
9.6.2.
Other display indications
The following table lists the messages which the display panel may show
WORDING DISPLAYED
MEANING
Off
The boiler is switched off
fan acc
Initial start-up sequence
load wood
Pellet loading
fire on
Start-up sequence and flame adjustment/stabilisation
Eco Stop
The boiler is automatically switched off when the temperature is reached
20 °C
Example of room temperature
62 °C
Example of water temperature
UT 01, UT02,…
User parameters to programme time, time brackets, etc...
day1,,,7
Days of the week
Set
Boiler operating mode setting (e.g. SET MAN = Boiler set to manual)
Alar fan fail
The smoke blower fan is malfunctioning
stop fire
Automatic brazier cleaning in the time interval set
red
red
cool fire
The boiler is in cooling mode
alar dep fail
The pressure switch was triggered and indicates a difficulty in evacuating smoke
alarm sond fumi
The smoke sensor is malfunctioning
alar no acc
There was a start-up failure.
alar no fire
There is no fire in the boiler
alar fail sic
Thermal cut-out alarm. Excess heat in the structure