red
COMPACT 24 BOILER
Chapter
9
USE AND MAINTENANCE MANUAL
page
33
Programming and settings
Technical dept. - All rights reserved - Reproduction prohibited
SET
TURBO
1
2
6
4
3
5
!
16
:
Ut 02
SET
TURBO
1
2
6
4
3
5
!
:
10
Ut 03
SET
TURBO
1
2
6
4
3
5
!
- - - -
set
SET
TURBO
1
2
6
4
3
5
!
+ 3
set
set
+ 3
9.1.1.
SETTING THE CURRENT TIME
Press in quick sequence buttons
and
to access technical
parameter
UT01. Press button
once to access item UT02 which
displays the hours. Use button
or
to decrease or increase the
hour.
To confirm the chosen hour and move on to the minutes setting, press
the
button.
(item
UT03 will be displayed)
Use buttons
or
to decrease or increase the minutes, in steps of
+/- 1 minute.
To confirm the chosen time and complete the setting, press
9.1.2.
Storing the recipe in the boiler.
THE RECIPE SELECTION PROCEDURE IS ONLY
ENABLED WITH THE BOILER TURNED OFF.
Press in rapid sequence or simultaneously buttons
and
.
“SET” will be displayed alternately with the recipe number. The recipes
are +3;+2;+1;0;-1;-2;-3.
Otherwise, if the display shows “- - - -”, this means no recipe is
currently selected (first start-up).
To quit the menu without making any changes, press the
button or
the
button or wait 120 seconds without pressing any buttons.
To modify or set a new recipe, press buttons
or
in order to find
the desired recipe.
To confirm your choice, you must hold down the
button until the display shows the time and the word
“OFF”.
The default boiler recipe is no. 0 for all versions and
for all Countries.
9.2.
ADJUSTING THE WATER TEMPERATURE IN
THE BOILER
The boiler is factory set with a series of standard parameters which
allow it to function correctly (water temperature of 65 °C and room
temperature of 22 °C) but if the user wants to change these
parameters, (s)he can do so as follows:
The parameters to be set are as follows:
Room T
This is the temperature you wish to reach inside the
room where the boiler is installed. To adjust it, press
ONCE the
“SET” button and change the values
using button
or
T H
2
O
= Maximum boiler water temperature. When this
temperature is reached, the boiler diminishes its
performance to avoid overheating. The standard
temperature set is 65 °C and it can be set to below 40 °C
or above 80 °C.
Sequence for accessing the hour and minutes
setting menu.
Phase 1: Example of entering the recipe menu
and displaying the previous setting
Phase 2: To choose the desired recipe, press
the buttons shown
First access to the recipe selection menu
Setting the system water temperature
Setting the room temperature
SET
TURBO
1
2
6
4
3
5
!
day 1
Ut 01
SET
TURBO
1
2
6
4
3
5
!
AMB
22°C
SET
TURBO
1
2
6
4
3
5
!
H2O
70°C