TV Process Var: (Tertiary Variable) The process variable that has been
assigned to this output (Mass Rate, Volume Rate, Std
Volume Rate, % Concentration, Concentration Rate,
Density and Temperature)
Process Var:
Present value of the selected output
Frequency:
The outputs present frequency value
% Range:
The present % of range for the selected output
Main Menu / 2. View Status / 1. View Status
List the process variables that are currently in alarm. This list is empty
when no alarms are active. Reviewing the list acknowledges any new
alarms. Acknowledged alarms are automatically removed from the list
when they return to normal.
Main Menu / 2. View Status / 2. View Error Log
List internal Datamate 2200 errors that have occurred.
Reviewing this
list does not acknowledge the errors. The Clear Error Log must be
performed.
Section 9.4 — Program Mode
Main Menu / 3. Program
Selection of this menu gives the user the option of entering the user
Password or of going directly to the Program menu. If the Program
menu is selected without first entering the correct password, the
configuration data will be displayed but cannot be changed. If an attempt
is made to change any configuration data, the error message “In Write
Protect Mode” will appear.
NOTE: This password is a 7-digit code that is independent of
the password entered into the Datamate 2200 via the keypad or
NexLink. When using the HHC, the configuration and programming
data may be changed using only this password and is not
protected by the password entered into the Datamate 2200.
THE DEFAULT PASSWORD IS “1111111”.
If an incorrect password is used, the message “Password entered
is incorrect” is displayed and the menu entry is exited. The “Enter
Password” option must be reselected to input the correct password.
When the correct password is entered, the menu will return to the
previous selections. Enter “Program” at this point and data may be
edited.
NOTE:
If the Datamate 2200 has been put in write protect mode via
the keypad or NexLink, even though a correct password has been
entered, the configuration of the device will not be changed. If this