Re
S.p.A.
ReVision II plus Touch
Rev.21/05/13
16/51
Encoder
If the Encoder is with single channel (to read the teeth number) or with double channel (to read
the teeth number and the start of print), it must be connected to the “sensor 1” connector.
Electrical connections:
RED wire (+24V)
Pin 9
BLACK wire (0V)
Pin 8
GREEN wire (CHA)
Pin 7
BLUE wire (CHZ)
Pin 6
YELLOW wire
NC
For a better protection of the electronics against the electrostatic discharges, connect the
metallic connector casing to the earth.
Technical features:
• Resolution: 100 impulses/turn
• Supply voltage: 5Vdc / 8÷24Vdc
• Current consumption without load: 80mA max • Switching output: NPN
• Output frequency: 100KHz max
• Protection class: IP54 – standard
• R.P.M. max: 3000 continuous
• Ambient operation temperature: 0 ÷ +60°C
• Ambient storage temperature: -25 ÷ +70°C
Mechanical dimensions:
Connect it to the print cylinder with the shaft or to stamp roller gears.