41
ENGLISH
DMS 6410 MICROPHONE CONSOLE DESCRIPTION
Every microphone console can be set to 1 of the 3 possible modes:
• Chairman
• Delegate
• Interpreter.
A basic system (without the optional board DEC 6104) can have:
a)
2 lines, each made of max. 30 DMS 6410 consoles (delegate / chairman; total: 60);
b)
2 interpreter consoles on dedicated lines;
c)
max. 3 chairmen (in all the system).
For instance, there can be 57 delegates, 3 chairmen and 2 interpreters.
An expanded system (including the optional board DEC 6104 and an additional power supply unit
DPS 6202) allows to connect further 4 console lines to connect up to 180 consoles (6 lines x 30
consoles / each).
Each console is to be initially set to a mode by means of its rear panel DIP switches:
The console setting should be done before switching the central unit DMU 6100 on; it can be done
also when the system is operating, but the new setting will be accepted after a system reboot.
DELEGATE / CHAIRMAN CONSOLE CONNECTION
Two 10 pole RJ sockets are present on the console rear panel for connections between 2 consoles
or between consoles and the DMU 6100 central unit.
Connections are made through special 10 pole cables. The input IN (on the right) is to be connected
to either the output OUT (on the left) of the previous console (of the same line) or 1 of the 2 (line 1 /
line 2) central unit outputs (if the console is the first of the line).
Every console can be connected to either the line 1 or the line 2; the only limit is max. 30 consoles
per line.
INTERPRETER CONSOLE CONNECTION
The 2 interpreter consoles (if available) shall be connected to the 2 dedicated central unit outputs.
1
2
OFF
OFF
DELEGATE
ON
ON
CHAIRMAN
OFF
ON
INTERPRETER
ON
OFF
(by-pass)