TM018 Raypak 131 Type A Pool & Spa Heaters REV: A
D.O.I: 8/04/2009
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
32
Fault Finding Chart 6
6
Replace EIB cable.
Plug EIB cable into correct
socket on main controller.
YES
NO
Is EIB cable continuous
and unbroken?
Is EIB cable plugged into
correct socket on main
controller?
NO
Correct socket is marked „E.I.B.‟
NO
(Manual mode)
YES
Does auxiliary(s) operate
using new EIB?
Replace EIB.
YES
Recover temporarily
connected new EIB and
replace main controller.
NO
Does controller display
„AUTO‟?
YES
(Auto mode)
Is controller clock set to
correct time?
Are auto mode time
periods programmed
correctly?
YES
Are auxiliary's
programmed to turn on
during auto mode time
periods?
YES
Is auxiliary(s) turned on?
YES
YES
Set controller clock to correct
time.
NO
Correctly program auto mode
time periods.
Auxiliary(s) must be
programmed to turn on during
auto mode time periods.
NO
NO
For information on programming
auxiliary operation in auto mode
refer to „TM055 Raypak Pool Heater
Controller Guide‟.
For information on selecting
auxiliary‟s whilst in manual mode;
refer to „TM055 Raypak Pool Heater
Controller Guide‟.
Temporarily connect
a new EIB.
Fault Finding Chart 7
7
Replace remote controller
cable.
Plug remote controller cable
into correct socket on main
controller.
YES
NO
Is remote controller cable
continuous and unbroken?
Is remote controller cable
plugged into correct socket
on main controller?
NO
Correct socket is marked „Remote‟
YES
YES
Does heater operate using
new remote controller?
Replace remote controller.
YES
Recover temporarily
connected new remote
controller and replace main
controller.
NO
Does heater function
using main controller?
1
NO
Temporarily connect
a new remote controller.