TM018 Raypak 131 Type A Pool & Spa Heaters REV: A
D.O.I: 8/04/2009
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
29
Fault Finding Chart 3
3
Is the water temperature
probe resistance value
correct?
Replace water temperature
probe.
NO
YES
Does water temperature
probe temp measured
above match controller
water temp?
Replace control board.
NO
Does flame icon
extinguish when set point
temp + 1º is reached?
NO
YES
Is 24 volts present at the
ignition module after
flame icon is
extinguished?
YES
YES
Test 18
Heater operating normally.
NO
Does burner extinguish
after flame icon
extinguishes?
Replace gas valve.
NO
YES
What was original
complaint?
Water too hot
(45ºC and/or 55ºC
high limits
NOT
tripping)
Free or replace in/out header
bypass valve.
YES
Is in/out header bypass
valve stuck in closed
position?
Clean internal blockage in
tube bundle or replace tube
bundle.
NO
Does in/out header
bypass valve have
correct spring?
YES
Replace bypass valve spring
with one of the correct colour.
NO
Is temp rise across heat
exchanger > 12ºC
NO
YES
Water too hot
(45ºC and/or 55ºC
high limits tripping)
Test 21